Industrial Edge RTU / HMI

Plunger lift,
run by the well.

The PK-E1107 puts a full app library, graphic keypad HMI, and every flavor of Modbus onto one rugged edge controller — so one box replaces the timer, the RTU, and the modem at the wellhead.

6
Lift Algorithms
9
I/O Channels
5
Modbus Paths
12–24V
DC Supply
PK-E1107 controller
PytroAI
Mobile App
Modbus RTU
Modbus TCP
Modbus Cellular
Modbus Radio
Keypad HMI
Overview

One controller,
every lift strategy.

PK-E1107 is an industrial edge controller built specifically for the artificial plunger lift market. PytroAI, a USB web interface, lets field techs browse, download, and install pre-built apps — Basic Timer, Time/Pressure Intermittent, Trigger, HiLo, Autocatcher, and PID control loops — over a simple USB connection, with no proprietary software to install.

A rugged HMI LCD and keypad lets operators manage lift operations right at the wellhead, in the field conditions natural gas wells actually run in. Built to run multiple apps at once, the PK-E1107 consolidates control, monitoring, and analytics onto a single device.

It speaks wired Modbus (RS-232, dual RS-485, Ethernet TCP) and wireless Modbus (LTE 4G, radio), plus Bluetooth for iOS/Android mobile app access — cutting hardware sprawl while keeping wells producing.

  • Pre-built lift algorithms, installed from PytroAI in minutes
  • Graphic LCD + F1–F6 keypad for at-well operation
  • 4 analog in, 2 analog out, 2 latching-valve outputs, 1 digital in
  • RS-232, dual RS-485, Ethernet, Cellular, Radio & BLE — all on one unit
  • MicroSD logging and coin-cell RTC for continuous records
PK-E1107 controller front panel with graphic LCD and F1–F6 keypad
// PK-E1107 — graphic LCD & keypad HMI, field-ready
PK-E1107 top panel showing radio, Bluetooth, GPS/GNSS and cellular antennas plus the labeled terminal strip
// Terminal strip & antenna deck — every port labeled on the enclosure
// Live at the wellhead — what the operator sees
READY
PK-E1107 MICROPYTHON EDGE
F1F2F3F4F5F6OKESC
Specifications

Built for the terminal strip and the field tech alike.

Six spec groups, straight off the datasheet — hardware, I/O, wired and wireless Modbus, the built-in lift apps, and the software stack.

Supply voltage12–24 VDC
DisplayGraphic LCD — 4×20
KeypadF1–F6, 0–9, Navigation
Real-time clockRTC coin-cell
StorageMicroSD card slot
USBDebugger, DFU update
Connectivity

Talk to it however your SCADA already talks.

Every path is Modbus — the PK-E1107 just changes the wire.

RS-232 & RS-485

One RS-232 Modbus RTU slave port, plus dual RS-485 — one slave, one master — for daisy-chaining downstream instruments.

Ethernet

Onboard Modbus TCP slave port for direct SCADA or PLC integration over the wired network.

Cellular LTE 4G

Modbus over cellular via API — remote telemetry for wells with no wired backhaul, on the -CELL variant.

900 MHz Radio

Long-range ISM-band radio, master or slave, configured through PytroAI — for pad-to-pad Modbus networks, on the -RADIO variant.

Bluetooth (PYBLE)

Standalone iOS & Android app for field configuration and diagnostics — no laptop required at the wellhead.

PytroAI (USB)

The web interface for installing apps, debugging over USB, and pushing firmware via DFU — no proprietary desktop software.

System Overview

One controller, the whole well site.

PK-E1107 reads pressure and arrival off the wellhead, drives the motor and injection valves, and runs on solar and battery power alone — no grid, no separate telemetry box.

BATT A — Sandstone B — Shale C — Limestone Casing Tubing Plunger Bumper spring / plunger stop RESERVOIR MASTER Casing Pressure TAP - CP GAS / CHEM SUPPLY INJECTION VALVE MOTOR VALVE Line Pressure TAP - LP SALES VALVE LP SEPARATOR TANK BATTERY Tubing Pressure TAP - TP Arrival Sensor TAP - AR LUBRICATOR / SHOCK SPRING SOLAR Remote Monitoring BATTERY BANK PK-E1107 INPUTS TP Tubing Pressure CP Casing Pressure LP Line Pressure AR Arrival Sensor OUTPUTS DO-1 Motor Valve DO-2 Injection Valve Solar + battery powered — no grid connection required Sensor to controller input Controller to valve output
Product Views

Every port, labeled on the case.

Front View — LCD & Keypad
Front View — LCD & Keypad
Top View — Antennas & Terminals
Top View — Antennas & Terminals
Connector Layout
Connector Layout
Ordering

Pick your radio, not your controller.

All three part numbers share the same core hardware and app library — the suffix just tells you which long-range radio is fitted at the factory.

Part NumberDescription
PK-E1107Artificial plunger lift controller. MicroPython edge engine, graphic LCD + keypad HMI. 1× arrival-sensor digital input, 2× latching-valve outputs, 4× analog inputs, 2× analog outputs. RS-232, dual RS-485 (master + slave), Ethernet (Modbus TCP). Cellular LTE 4G, radio & BLE optional. MicroSD, RTC. Supply 12–24 VDC.
PK-E1107-CELLPK-E1107 with cellular LTE 4G module fitted for remote telemetry. All features as above.
PK-E1107-RADIOPK-E1107 with long-range 900 MHz radio module fitted. All features as above.
Conformity

Reference summary.

Controller function
Artificial plunger lift control
Supply voltage
12–24 VDC
Edge engine
MicroPython, user-defined algorithms
Serial protocols
Modbus RTU (RS-232, RS-485)
Network protocol
Modbus TCP (Ethernet)
Wireless
Cellular LTE 4G, Radio, Bluetooth (PYBLE)
Control algorithms
Basic Timer, Time/Pressure Intermittent, Trigger, HiLo, Autocatcher, PID1/PID2
Certification
IC, FCC
Warranty
1 year standard — see pytrowell.com/warranty

Talk to us